Model : Met One 3400 | Category : Portable Particle Counters | Brand : Beckman Coulter
 
The MET ONE 3400 portable air particle counter is designed specifically for ISO14644 cleanroom applications. Organize your routine cleanroom monitoring with embedded location and sample recipe management. The MET ONE 3400 portable air particle counter classification wizard assures compliance during periodic cleanroom certification. Also visit MET ONE 3400 Simply Paperless!


Benefits

Hot-swappable batteries –100% instrument availability
Hot-swappable batteries eliminate the need to stop measuring while your instrument charges or for powering down, zero counting and powering back up. Test wizard for easier compliance - organize your cleanroom
Save time and eliminate errors when monitoring your cleanroom environments. Flexible communications - easy setup and data transfer
Reduce your paperwork with wireless, Ethernet and serial communication options to MET ONE Data Management or your own software solutions. Intuitive user interface
Easily set up sampling plans by area, location and operating parameter, saving operator time. Eliminate setup errors and save time by exporting setup configuration to USB memory stick and deploy your sampling plan across your entire particle counting fleet! Multiple user login - assures compliance
Password protected multi-level user access to instrument provides data security for 21 CFR Part 11 compliance. ISO 21501-4 reliability and accuracy
Designed for exceptional particle counting performance providing ISO 21501-4 compliant unit-to-unit accuracy and reproducibility. Sequential sampling - manifold system
Low cost site monitoring solutions can be deployed with the MET ONE Model 3432 manifold. Sample sequentially from up to 32 locations with a single MET ONE Model 3400 airborne particle counter.

  • Cleanroom environmental monitoring
  • Cleanroom classification
  • ISO 14644 cleanroom verification
  • Cleanroom validation
  • Cleanroom particulate monitoring
  • Aseptic pharmaceutical production
  • Continuous monitoring of manufacturing processes
  • Process troubleshooting particle contamination sources
  • Validating cleanrooms to comply with manufacturing regulations and standards
  • HEPA filter leak detection
  • High pressure gas monitoring with simple gas selection menu and automatic sample flow adjustment

Airborne Particle Counter Life Sciences Standards and Committees


Included

Part Number Description
2087966-01 Isoprobe 1.00 CFM AL 3/8 Barb, For use with aseptic agents please order the optional Stainless Steel Isoprobe & adapter listed below.  (P/N 2087966-02 & P/N 2088035-02)
960380 Tubing, sample, 3/8” ID, 10 ft  (price per foot)
2088035-01 Isoprobe Adapter, AL
970650 Tripod for Isoprobes. (requires adapter P/N 2088035-01) For use with aseptic agents please order the optional Stainless Steel Isoprobe Stand listed below. (P/N 2088403-02)
701241 Manual, Owners Operating
230-300-7052 Power Supply, +24 VDC @ 3A
400105 Power Cord, 115 VAC
510667 Power Cord, 220 VAC
2087939-01 Zero Count Filter (1.0 CFM models)
460519 Printer paper, 2 rolls included
280-120-2024 Battery pack, smart lithium ion
210-400-5171 Stylus Touch screen instrument
995240 Cleaning brush, stainless steel
2088010-01 USB memory drive 128M
490-200-0001 Wireless Antenna Included with wireless version P/N 2088900-01-W


Spec Value
Standard Size Channels 3413 and 3423 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
3415 and 3425 0.5, 1.0, 2.0, 3.0, 5.0, 10.0 or 0.5, 1.0, 2.0, 3.0, 5.0, 25.0* μm
3445 0.5, 1.0, 2.0, 3.0, 5.0, 10.0um
Flow Rate 3413 and 3415 28.3 LPM (1.0 CFM) ± 5% (default factory setting)
3423 and 3425 50 LPM (1.77 CFM) ± 5% (default factory setting)
3445 100LPM (3.53 CFM) ± 5% (default factory setting)
Zero Count Conforms to JIS B9921. 1 count or less in 5 minutes, 95% confidence level
Coincidence Loss 28.3 LPM (1.0 CFM) 5% at 14,126,000 particles/m3 (400,000 particles/ft3) 50 LPM (1.77 CFM) 5% at 4,000,000 particles/m3 (113,266 particles/ft3) 100 LPM (3.53 CFM) 10% at 10,000,000 particles/m3 (283,166 particles/ft3)
Counting Efficiency 3413 and 3423 50% ± 20% for 0.3um (100% ± 10% at 1.5 times the minimum sensitivity), fully complies with ISO 21501-4
3415, 3425 and 3445 50% ± 20% for 0.5um (100% ± 10% at 1.5 times the minimum sensitivity), fully complies with ISO 21501-4
Light Source Long Life Laser™ diode with 10-year Mean Time To Failure (MTTF)
Pump Type Air vacuum, rated for continuous use
Count Display Color 1/4 VGA TFT Touch Screen
Interface Windows CE®-based
Sample/Hold/Delay Times 1 second to 23 hrs 59 minutes 59 seconds
Count Alarms 1 to 9,999,999 counts
Count Cycles Up to 100 while in automatic mode
Location Labels 0 to 999, appears on printout
Data Storage 5,000 samples, scrollable on Historical Data review screen
Communication Interfaces RS232, RS485, 802.11 b/g Wireless, 802.3 Ethernet, USB Client (Version 1.1), USB Host (Version 1.1)
Communication Protocol Modbus TCP, Modbus RTU, Serial FX
Battery Type Lithium ion smart battery; rechargeable, ejectable and hot-swappable
Operating Time (Battery) 28.3 LPM (1.0 CFM) 6 hours** 50 LPM (1.77 CFM) 6 hours** 100 LPM (3.53 CFM) Up to 3 hours**
Battery Recharge Time 6.75 hours minimum, 10 hours maximum
Power 24 VDC 3.2A with 100~240 VAC 50/60 Hz adapter (included in ship kit)
Size, Dimensions 31.8 W x 25.4 D x 20.3 H cm (12.5 x 10 x 8 inches)
Weight (without battery) 3413 and 3415 7.55 kg (16.6 lbs) 3423 and 3425 8.33 kg (18.3 lbs) 3445 8.65 kg (19.0 lbs)
Enclosure Material Stainless Steel
Environment Operating 0 to 40° C (32 to 104° F), 10 to 90% relative humidity, non-condensing Storage -40 to 50° C (-40 to 122° F), 0 to 98% relative humidity, non-condensing
* Channel selections can be selected at time of order in a range from 0.3 μ to 25 μ. However 0.3 μ and 25 μ cannot be configured together.
** Battery life is estimated with these conditions: The 1.77 cfm unit sampling for 20 minutes (1 m3) sample, print record, a 5-minute hold time (simulating move to new location), then repeat this cycle. Backlight sleep time is set at 2 minutes. The 1.0 cfm unit, sample time is set at one minute, print record, a 1-minute hold time (simulating continuous sampling mode), then repeat this cycle. Backlight would remain on at all times.